BQFXV - GV SERIES GLOSS VINYL SCREEN INK, GV142
- MSDS: BQFXV
- Manufacturer: NAZDAR CO
- Product Name: GV SERIES GLOSS VINYL SCREEN INK, GV142
- National Stock Number: 7510-00N035157
Product Identification
Product ID:GV SERIES GLOSS VINYL SCREEN INK, GV142
MSDS Date:08/22/1989
FSC:7510
NIIN:00N035157
MSDS Number: BQFXV
Responsible Party
CHICAGO, IL 60622
US
Emergency Phone: 312-943-8338
Info Phone: 312-943-8338
Cage: FO883
Contractor
Telephone: 312-943-8338;800-736-7636
Cage: 76708
Ingredients
2-CYCLOHEXEN-1-ONE,3,3,5-TRIMETHYL-;(ISOPHORONE) (SARA
CAS: 78-59-1
RTECS: GW7700000
Fraction By Weight: 35-40%
OSHA PEL 25 PPM
ACGIH TLV: C 5 PPM; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
5 @ 100F.
CAS: 64742-94-5
RTECS: WF3100000
Fraction By Weight: 10-15%
OSHA PEL 500 PPM (MFR)
PROPIONIC ACID, 3-ETHOXY-, ETHYL
CAS: 763-69-9
RTECS: UF3325000
Fraction By Weight: 5-10%
PIGMENTS CONTAINING INGREDIENTS INGREDIENTS 5-7.
Fraction By Weight: 5-30%
ACGIH TLV: 10 MG/M3 DUST (MFR)
1) (SARA III)
CAS: 7446-14-2
RTECS: OG4375000
Fraction By Weight: 5-15%
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.15 MG/M3 (PB)
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
1);(LEAD CHROMATE)
CAS: 7758-97-6
RTECS: GB2975000
Fraction By Weight: <5%
OSHA PEL 1 MG/M3 (CR)
ACGIH TLV: 0.5 MG/M3 (CR)
COPPER (SARA III)
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: <5%
OSHA PEL 0.1MG/M3 FUME;1 DUST
ACGIH TLV: 0.2MG/M3 FUME;1 DUST
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
650 G/L
RTECS: 9999999VO
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT WITH THE LIQUID, ITS
VAPORS OR MISTS MAY CAUSE BURNING, TEARING, AND REDNESS. SKIN
CONTACT MAY CAUSE IRRITATION. INHALATION MAY CAUSE RESPIRATORY
TRACT IRRITATION OR NERVOUS SYSTEM DISORDE RS SUCH AS HEADACHES,
DIZZINESS AND FATIGUE. INGESTION MAY CAUSE GASTROINTESTINAL TRACT
IRRITATION (EFTS OF OVEREXP)
Explanation of Carcinogenicity:LEAD CHROMATE:KNOWN CARCINOGEN (NTP),
GROUP 1 (IARC).
Effects of Overexposure:HLTH HAZ:AND SIGNS OF NERV SYS DEPRESS.
RPTD/PRLNGD OVEREXP BY INHAL OR SKIN ABSORPTION MAY CAUSE BLOOD
DISORDERS. RPTD/PRLNGD OVEREXP TO LEAD BY INGEST MAY CAUSE METALLIC
TASTE IN MOUTH, NAUS & DIGES TIVE DISORDERS, ABDOMINAL CRAMPS &
INSOMNIA AS WELL AS BLOOD, NERV, URINARY & REPROD DISORDERS & BIRTH
DEFECTS. (SUPDAT)
Medical Cond Aggravated by Exposure:PRESONS WITH PRE-EXISTING SKIN OR
LUNG DISORDERS MAY BE MORE SUSCEPTIBLE TO EHE EFFECTS OF THIS
MATERIAL.
First Aid
First Aid:SKIN:WASH WITH SOAP & WATER, CALL MD IF IRRITATION PERSISTS.
EYE:FLUSH WELL WITH RUNNING WATER FOR AT LEAST 15 MINUTES, CALL MD
IF IRRITATION PERSISTS. INHAL:MOVE TO FRESH AIR, RESTORE BREATHING,
CALL MD. INGEST:CALL MD OR POISON CONTROL CENTER IMMEDIATELY.
Fire Fighting
Flash Point Method:SCC
Flash Point:136F,58C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . WATER MAY BE INEFFECTIVE BUT MAY BE USED TO
COOL CLOSED CONTAINERS.
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELECTRICAL EQUIPMENT,
SPARKS AND OPEN FLAME. CLOSED CONTAINERS MAY EXPLODE WHEN EXPOSED
TO EXTREME HEAT.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE
AREA. AVOID BREATHING VAPORS. CONTAIN RELEASE AND REMOVE WITH INERT
ABSORBENT. AVOID CONTACT. USE NON-SPARKING TOOLS TO PLACE MATERIAL
IN APPROPRIATE CONTAINE R FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN CLOSED CONTAINERS IN COOL,
DRY, WELL VENTILATED AREA AWAY FROM SOURCES OF IGNITION. KEEP
CONTAINERS CLOSED WHEN NOT IN USE.
Other Precautions:AVOID PROLONGED OR REPEATED OVEREXPOSURE TO THIS
PRODUCT. EMPTY CONTAINERS SHOULD BE DISPOSED OF IN AN
ENVIRONMENTALLY SAFE MANNER IN ACCORDANCE WITH APPLICABLE
REGULATIONS. SMOKE IN DESIGNATED AREAS ONLY.
Exposure Controls
Respiratory Protection:IF VAPOR CONCENTRATION EXCEEDS THE TLV LISTED,
USE A NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC CHEMICAL
CARTRIDGE. CONTACT A REPUTABLE SAFETY SUPPLY COMPANY FOR THE
APPROPRIATE RESPIRATOR.
Ventilation:AS REQUIRED TO KEEP VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:NEOPRENE OR NITRILE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SOLVENT RESISTANT APRONS. EYE WASH.
Work Hygienic Practices:WASH W/SOAP & WATER BEFORE EATING, SMOKING OR
USING TOILET FACILITIES. REMOVE CONTAM CLTHG TO PVNT PRLNGD SKIN
CONTACT.
Supplemental Safety and Health
EFTS OF OVEREXP:REPORTS HAVE ASSOCIATED REPEATED AND PROLONGED
OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING & INHALING THE CONTENTS MAY BE HARMFUL ORFATAL.
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:>315F,>157C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Spec Gravity:1.12
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, AND OPEN FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
OTHER NOXIOUS GASES.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL,
COUNTY, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.